Judul ArtikelEVALUASI SISTEM INSTALASI PENGOLAHAN AIR LIMBAH DI RUMAH SAKIT UMUM HIDAYAH PURWOKERTO TAHUN 2017
AbstrakLatar belakang : Rumah sakit merupakan institusi yang menjalankan kegiatan pelayanan preventif, kuratif, rehabilitatif dan promotif. Kegiatan ini menghasilkan limbah padat, cair, dan gas.Limbah cair dapat menimbulkan penyakit dan pencemaran lingkungan sehingga perlu pengelolaan limbah khusus. Pengukuran kualitas air limbah Rumah Sakit Umum Hidayah tahun 2015 didapatkan Chemical Oxygen Demand (COD) 173 mg/l, amoniak 0,39 mg/l dan kandungan coliform 46 x103 MPN/ 100 ml. Metodologi : Penelitian ini merupakan penelitian deskriptif dengan pendekatan kuantitatif. Sumber informasi terdiri dari data sekunder dan data primer.Metode penelitian dilakukan dengan pengukuran outlet secara langsung, observasi dan pengolahan data sekunder. Hasil Penelitian : Hasil penelitian menunjukkan limbah cair di RSU Hidayah Purwokerto berasal dari linen, gizi, laboratorium, kamar operasi dan radiologi. Pengolahan air limbah menggunakan biofilter upflow anaerobic sludge blanket (UASB). Hasil Outlet instalasi pengolahan air limbah (IPAL) dibuang ke Sungai Mersi. Hasil pengukuran terhadap Outlet, kadar COD 304 mg/l (BML 80), amoniak 0,07 mg/l (BML 0,1) dan kandungan coliform 544 x 106 MPN/ 100 ml (BML 5000). Kesimpulan : Secara IPAL RSU Hidayah Purwokerto belum baik. Parameter COD dan kandungan coliform belum memenuhi standar baku mutu Perda Jateng No. 5 Tahun 2012.
Abstrak (Inggris)Background :The hospital is an institution that service activities of preventive, curative, rehabilitative and promotive. These activities produce solid, liquid, and gas waste. Liquid waste can cause diseases and environment pollution need special waste management. Measurement of quality waste water Public Hospital Hidayah in 2015 with result Chemical Oxygen Demand (COD) 173 mg/l, ammonia 0,39 mg/l and coliform content 46 x103 MPN/ 100 ml. Method :This study is a descriptive research with quantitative approach. Sources of information consist primary and secondary data. The research are using depth direct measurement of influent, observation and secondary data process. Result :The results showed that the liquid waste at Public Hospital Hidayah Purwokerto derived from linen, nutritionis, laboratory, operating room and radiology . Liquid waste management is using biofilter upflow anaerobic Sludge Blanket (UASB). Result of effluent Instalation Waste Water Treatment Process (WWTP) dumped in the Mersi’s river. Measurement result of effluent, COD levels 304 mg/l (BML 80), ammonia 0,07 mg/l (BML 0,1) and coliform contents 544 x 106 MPN/ 100 ml (BML 5000). Conclusion: Generally, IWWTP RSU Hidayah Purwokerto is not good. COD parameter and coliform contents was not yet meet quality standard Perda Jateng No. 5 Tahun 2012.
Kata KunciIPAL, Air Limbah, UASB
Nama Pembimbing 1Saudin Yuniarno, S.KM., M.Kes
Nama Pembimbing 2Agnes Fitria W., S.KM., M.Sc
Tahun2017
Jumlah Halaman10
Page generated in 0.0569 seconds.