Judul ArtikelPERHITUNGAN DOSIS SERAP RADIASI SUMBER Ir-192 UNTUK BRACHYTHERAPY KANKER PROSTAT DAN ORGAN SEKITARNYA MENGGUNAKAN METODE MONTE CARLO
AbstrakABSTRAK — Brachytherapy merupakan salah satu bentuk radioterapi yang dapat dilakukan untuk mengobati penyakit kanker prostat. Banyaknya implan dari sumber radioaktif iridium-192 yang ditanam perlu diketahui jumlah optimal untuk memastikan tingkat keamanan sebelum melakukan terapi. Penelitian ini bertujuan untuk mengetahui nilai dosis serap radiasi pada organ yang terkena sel kanker dan organ at risk serta untuk mengetahui berapa jumlah sumber radiasi yang harus ditanam selama terapi berlangsung yang menghasilkan nilai dosis optimal. Tahapan yang dilakukan dalam penelitian meliputi pemodelan sumber radiasi dan phantom inhomogen daerah sekitar kanker, running program dan pengolahan data hasil running. Nilai dosis serap radiasi berdasarkan interaksi foton pada organ dapat diperoleh menggunakan code tally f8 dalam input user code MCNPX. Berdasarkan hasil penelitian, nilai dosis serap yang diterima setiap organ berhasil diperoleh. Jumlah implan optimal yang memberikan nilai dosis serap optimum yaitu sebesar 19 gray untuk satu kali fraksi dan sesuai dengan referensi adalah sebanyak 12 implan. Selain itu, variasi sumber radiasi iridium-192 yang diimplankan memberikan pengaruh yang signifikan terhadap kenaikan dosis serap yang diterima setiap organ. Sumber iridium-192 yang divariasikan masing-masing sebanyak 12, 13, 14, 15, 16, 17, 18, 19 dan 20 sumber. Semakin banyak jumlah sumber radiasi yang diimplankan maka nilai dosis serap yang diterima setiap organ juga semakin besar .
Abstrak (Inggris)ABSTRACT — Brachytherapy is a form of radiotherapy that can be done to treat prostate cancer. The number of implants from planted iridium-192 radioactive sources needs to be known to the optimal amount to ensure the level of safety before conducting therapy. This study aims to determine the value of radiation absorbed dose received by organs affected by cancer cells and organs at risk and to find out how many sources of radiation that must be planted during therapy that results in optimal dose values. The stages carried out in this study include modeling the source of radiation and phantom inhomogen areas around cancer, running programs and processing the results of running data. Radiation absorption dose values based on photon interactions in organs can be obtained using the tally f8 code in the MCNPX input. Based on the results of the study, the absorbency dose received by each organ was successfully obtained. The optimal number of implants that provide the optimum absorption dose is 19 gray for one fraction and in accordance with the reference is 12 implants. In addition, variations in the iridium-192 radiation source implied have a significant effect on the increase in the absorbed dose received by each organ. The sources of iridium-192 varied as many as 12, 13, 14, 15, 16, 17, 18, 19 and 20 sources. The greater the number of sources of radiation implied, the greater the value of absorbed doses received by each organ.
Kata Kunci Brachytherapy, kanker prostat, dosis serap radiasi, MCNPX
Nama Pembimbing 1Aris Haryadi
Nama Pembimbing 2Mukhtar Effendi
Tahun2020
Jumlah Halaman19
Page generated in 0.0509 seconds.