Judul ArtikelPemodelan Untuk Menunjang Penilaian Kinerja Pesawat Sinar-X Mobile Diagnost Wdr Versi 2.2
AbstrakPada penelitian ini telah dilakukan pemodelan untuk menunjang penilaian kinerja pesawat sinar-X Mobile Diagnost Wdr Versi 2.2 terhadap alat peraga abdomen yang dibuat menggunakan bahan akrilik-aluminium. Parameter karakterisasi yang dilakukan dalam penelitian ini yaitu uji massa jenis, uji koefisien atenuasi massa, uji kualitas citra, uji hamburan radiasi, dan uji dose area product. Penelitian ini dilakukan dengan menggunakan alat dan bahan diantaranya Pesawat sinar-x DR, neraca digital, detector PIRANHA, Surveymeter, Penggaris, Meteran, In-house Phantom, Laptop, Sofware ocean, Sofware MATLAB, Sofware image-j, akrilik, dan aluminium. Hasil yang diperoleh dalam penelitian ini adalah nilai massa jenis akrilik dan aluminium masing-masing bernilai 1,18 g/cm3 dan 2,70 g/cm3 mendekati nilai massa jenis soft tissue dan hard tissue. Nilai regresi koefisien atenuasi massa akrilik dan aluminium masing-masing bernilai R2=0,98dan R2=0,9544. Kualitas citra phantom abdomen yang memiliki tegangan dan arus yang paling optimal menurut parameter CV, CL, MTF berada pada faktor eksposi 80 kV dan 32 mAs.
Abstrak (Inggris)In this study, modeling was carried out to support the performance assessment of the X-ray Mobile Diagnostics Wdr Version 2.2 of the abdominal props made using acrylic-aluminum material. Characterization parameters carried out in this study are density test, mass attenuation coefficient test, image quality test, radiation scattering test, and product area dose test. This research was conducted using tools and materials including x-ray DR aircraft, digital balance, PIRANHA detector, Surveymeter, Ruler, Meter, In-house Phantom, Laptop, Ocean software, MATLAB software, image-j software, acrylic, and aluminum. The results obtained in this study are the density values of acrylic and aluminum, respectively 1.18 g / cm3 and 2.70 g / cm3 close to the density values of soft tissue and hard tissue. The regression values of the mass attenuation coefficient of acrylic and aluminum are R2 = 0.98 and R2 = 0.99, respectively. Abdominal phantom image quality which has the most optimal voltage and current according to the parameters CV, CL, MTF is at the exposure factor of 80 kV and 32 mAs.
Kata KunciAbdomen, Akrilik, Aluminium, Pesawat sinar-x DR, uji massa jenis, uji koefisien atenuasi massa, uji kualitas citra.
Nama Pembimbing 1Dr. Eng. Mukhtar Effendi
Nama Pembimbing 2Agus Sholeh S.Si
Tahun2020
Jumlah Halaman6
Page generated in 0.0516 seconds.