Judul ArtikelPENGARUH VARIASI TEGANGAN TERHADAP PERGESERAN LUASAN KOLIMASI PESAWAT SINAR-X PADA PHANTOM THORAX DEWASA DENGAN METODE MONTE CARLO
AbstrakVariasi tegangan pemercepat elektron terhadap pergeseran luasan kolimasi sinar-X pada phantom thorax telah disimulasi dengan metode Monte Carlo menggunakan user code MCNPX. Tujuan penelitian adalah untuk memberikan informasi secara kuantitatif pengaruh tegangan terhadap pergeseran luasan kolimasi pada diagnostik thorax dewasa dengan mengamati profil radiasi, dan spektrum radiasi secara simulasi. Spektrum yang dihasilkan tegangan 55 kV diperoleh energi 17 keV sebesar 8,22×10-20, energi yang dihasilkan masih dibawah persyaratan diagnostik. Sedangkan, spektrum tegangan 85 kV diperoleh energi 58 keV sebesar 1,35×10-16, energi yang dihasilkan memenuhi persyaratan diagnostik, karena spektrum yang dihasilkan masih dalam jangkauan diagnostik (40 keV – 90 keV). Hasil penelitian menunjukkan bahwa tegangan 85 kV lebih baik digunakan pada thorax dewasa. Simulasi operasi tegangan pesawat sinar-X pada sumbu-X tegangan 55 kV diperoleh pergeseran sebesar 3 cm, dan penyimpangan melebihi batas toleransi yang diberlakukan (X1 + X2 ≤ 2 cm). Untuk tegangan 85 kV diperoleh pergeseran sebesar 1 cm, dan penyimpangan masih dalam batas toleransi yang diberlakukan. Sedangkan, tegangan 55 kV dan 85 kV pada sumbu-Y megalami pergeseran luasan kolimasi sebesar 1 cm, dan penyimpangan masih dalam batas toleransi yang diberlakukan. Pergeseran luasan kolimasi dapat terjadi akibat kemiringan cermin yang tidak sesuai, dan berpengaruh terhadap pantulan cahaya dari lampu kolimasi yang keluar dari kolimator. Penambahan tegangan pada pesawat sinar-X dapat menyebabkan pergeseran luasan kolimasi yang berpengaruh terhadap kualitas citra.
Abstrak (Inggris)The variation of the electron accelerator voltage to the X-ray collimation area in the thoracic phantom has been simulated using the Monte Carlo method using the MCNPX user code. The purpose of the study was to quantitatively inform the effect of voltage on the area of collaboration in thorax diagnostics by observing the radiation profile, and radiation spectrum in a simulated manner. The spectrum produced by a voltage of 55 kV obtained an energy of 17 keV of 8.22×10-20, the energy produced is still below the diagnostic requirements. Meanwhile, the voltage spectrum of 85 kV obtained 58 keV energy of 1.35×10-16, the energy produced meets the diagnostic requirements, because the resulting spectrum is still within the diagnostic range (40 keV – 90 keV). The results showed that a voltage of 85 kV is better to use on an thorax. A simulation of the voltage operation of the X-ray plane on the X-axis of a voltage of 55 kV obtained a shift of 3 cm, and a deviation exceeding the imposed tolerance limit (X1 + X2 ≤ 2 cm). For a voltage of 85 kV a shift of 1 cm is obtained, and the deviation is still within the limits of the imposed tolerances. Meanwhile, the voltage of 55 kV and 85 kV on the Y-axis is subject to the area of the collaboration by 1 cm, and the deviation is still within the imposed tolerance limit. The area of collimation can occur due to inappropriate tilt of the mirror, and affect the reflection of light from the collimation lamp coming out of the collimator. The addition of voltage to the X-ray plane can cause area of the collimation which affects the quality of the image.
Kata KunciPhantom thorax, MCNPX, Spektrum, Pergeseran luasan kolimasi
Nama Pembimbing 1Aris Haryadi S.Si.,M.Si
Nama Pembimbing 2Dr. Bilalodin S.Si.,M.Si
Tahun2023
Jumlah Halaman13
Page generated in 0.0547 seconds.